Skip to content Skip to sidebar Skip to footer

Gas Logs Electronic Ignition System

Gas Log and Burner Intermittent Ignition with Remote Control Intermittent pilot electronic ignition systems are a battery powered electronic ignition system which include a remote. FOR YOUR SAFETY If you smell gas.


Fiberglow Series Gl24ne 24 Vented Natural Gas Log Set With Electronic Ignition Up To 60 000 Btu S Phazer Log Set C Gas Log Sets Gas Logs Natural Gas Fireplace

Exquisitely detailed realistic logs with char chamber.

Gas logs electronic ignition system. Some gas fireplaces can be upgraded with electronic ignition systems to boost fuel conservation and efficiency. Electronic ignition gas ignition systems use a flame sensor that measures microamps to prove the flame. Most new gas appliances driers hot water heaters and forced air systems are actually required to be manufactured with electronic ignition systems because of the annual fuel savings.

Phoenix AZ 85040 P602-344-4217 F 602-243-6523 1 GCRK INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS ELECTRONIC IGNITION SYSTEM GRAND CANYON GAS LOGS USES ROBERTSHAW 712 SERIES FLAME RECTIFICATION CONTROLS agency or gas supplier HAZARDOUS CONDITION. There is not a standing pilot light. If the main burner ignites within the 4-7 second ignition try the control module generates a small electrical current that passes from the flame rod through the flame to the burner it is now converted to DC.

CALIFORNIA PROPOSITION 65 WARNING. 3515 East Atlanta Ave. Electronic ignition gas systems do not use a thermocouple or thermopile to prove the flame.

Electronic ignition systems generally require the use of 110v 120v electricity to operate. The controls are. Hands down this is the best looking log set because of the slope glaze burner design the flame is very active and not defined as with other brands.

F FX and DF-CF with the Valve Vanisher TM EIS and Millvolt controls are certified to ANSI-Z2160 Decorative Fireplace Gas Log Standard. An electronic ignition system also known as a non-standing pilot eliminates the hassle of igniting your fireplace with matches or a long lighter. The electronic ignition system does not stay lit when your logs are turned off.

Electronic ignitions all work in much the same way once the fire is turned on by the user an electronic signal first turns on the pilot light. Variable flame height remote control with thermostat feature in the hand-held transmitter. Electronic Ignition eliminates the wasted fuel of a standing pilot while providing better safety protection.

Accent light highlights logs with or without the fire on. As the control module is generating sparks it also powers the 24 vac gas control valve to allow gas to flow for about 4-7 seconds. This feature saves energy because you are not burning gas when the logs are off.

Complete electronic ignition kit uses Dexen EI gas valve 82k Btu that may be controlled with a wall switch remote control or timer. Dexen Electronic Ignition Valve 350 82k Btu. Weather Beater Electronic Control System Model.

The EIS system used with the Valve. Gas logs are an exception at. An electronic gas ignition system utilizes solid-state controls for igniting the flame and proving the flame.

Intermittent pilot ignitions operate as follows once the fire is turned on by the user an electronic signal first turns on the pilot light. Owners Operation and. This product can expose you to.

After the pilot light is confirmed on the electronic unit then allows for the burner to open. Electronic Ignition Systems are powered by four AA batteries included. Automatic pilot ensures the pilot is operating in cold weather recommended for reliable operation of direct vent gas hearth products in cold climates.

The system does not have. How Gas Logs with Electronic Ignition Compare to Gas Logs with a Safety Pilot. It is battery operated so there are no wires needed.

After the pilot light is confirmed on the. Shut off gas to appliance. When gas logs first come out they had a match lit ignition meaning you turned a knob to let the gas out and then lit it with a match.

Flame Wireless Remote Control Can be set at the maximum BTU 33000 C5A models or 40000 C5B models BTUhour or turned down with manual valve to 16000 BTUhour or any point in between. This applies whether you retrofit your old fireplace or. This is a Real Fyre Electronic Ignition Remote Ready Valve System to be used with certain Real Fyre Gas Log Burners.

Electronic ignition system with battery back-up saves energy and works in a power failure. This 18 inch electronic ignition Empire Charred Oak gas log set by White Mountain Hearth is vent free and requires no vent or chimney. When the flame sensor becomes fouled it can prevent the proper amount of microamps from being read by the.

Electronic ignition gas logs will soon be mandatory by the EPA because they conserve fuel and save the customer money over time. The charred oak logs are molded from real wood and painted to match being the most realistic. The savings you realize from the use of an electronic system will far outweigh the small cost of the change.

With an electronic ignition system upgrade you can turn your fireplace On and Off or even adjust the flames height with a remote control--all from the snug coziness of your favorite living room spot. This kit is battery operated in the event of power outage- Optional 120Vac adaptor available. Then came the safety pilot with a piezo ignition on log set that you pushed a button that created a spark in front of the pilot that heated then.

2Extinguish any open flame. Electronic Ignition System. Electronic Ignition valve kit with flex line connection to main burner.

Grand Canyon Gas Logs LLC. If odor continues keep away from appliance and im - mediately call your gas supplier or fire department. Buy products from suppliers around the world and increase your sales.

Electronic Ignition System no standing pilot. This type of ignition system includes intermittent pilot ignitions power is stepped sown and direct ignitions uses direct 110120v electricity. The 9-volt battery powered hand-held transmitter is included and is used to turn the burner on raise and lower the flame and turn the burner and pilot off.


Homepage Gas Firepit Natural Gas Fire Pit Gas Fire Pits Outdoor


Superior Fireplaces Contemporary Direct Vent Natural Gas Fireplace Insert With Electronic Ignition System Gas Fireplace Insert Fireplace Inserts Gas Fireplace


Pin On Gazebo Patio


Ascent Series B36ntr 35 Direct Vent Natural Gas Fireplace With Millivolt Ignition Up To 18 000 A Gas Fireplace Natural Gas Fireplace Propane Gas Fireplace


All Weather Electronic Ignition System Standard Capacity Woodland Direct Diy Gas Fire Pit Gas Firepit Ignition System


Napoleon Bhd4stfcn 30000 Btu Built In Direct Build Com Two Sided Fireplace Direct Vent Gas Fireplace Fireplace


42 Artisan Total Signature Command Vent Free Linear Fireplace Electronic Ignition Monessen Gas Fireplace Monessen Fireplace


How Electronic Ignition Ipi Fireplaces Work Chimney Works Rocky Mountain Stoves Prevent Gas Ignite Fireplace


Pin On Porches


Pin On Products


The Bgd36 Direct Vent Gas Fireplace Features Napoleon S 100 Safe Guard Gas Control System Corner Gas Fireplace Vent Free Gas Fireplace Corner Fireplace Decor


Pin On Airstone Fireplace


Napoleon Ascent 30 Direct Vent Gas Fireplace With Electronic Ignition In 2021 Vented Gas Fireplace Direct Vent Gas Fireplace Gas Fireplace


Pin On Fireplace


Napoleon L38n Acies Series Electronic Ignition Direct Vent Gas Fireplace Direct Vent Gas Fireplace Vented Gas Fireplace Gas Fireplace


Sierra Flame Langley 36 Direct Vent Linear Gas Fireplace Fireplacesrus Direct Vent Gas Fireplace Vented Gas Fireplace Gas Fireplace


Greenfire Gf1500l Gas Fireplace Shown With Clean Edge Luxury Bedroom Sets Gas Fireplace Luxurious Bedrooms


Superior Drt3540 Pro Series 40 Top Rear Vent Fireplace With Aged Oak Logs Electronic Ignition Vented Gas Fireplace Direct Vent Gas Fireplace Gas Fireplace


Honeywell Mvk Eimc 1 Electronic Ignition Valve Kit Natural Gas Click Image For More Details Affiliate Link Gas Fireplace Fireplace Accessories Fire Ring


Post a Comment for "Gas Logs Electronic Ignition System"